客服电话:021-5835-7237 173-2132-1081 180-1647-9018
气体中的杂质,例如烃类,水分,氧气可以污染传输线和仪器,导致色谱柱性能下降并且影响分析结果的准确性,这可能导致仪器停机。即使使用高纯气体,压力调节器或者其它部分的管路依然可以带入污染物,因此外加气体过滤器是非常必要的。
确保高纯度的气体
岛津的超净过滤器可以去除杂质(烃类,水分,氧气)并且保证出口99.9999%的纯气。高纯度和无污染的气体减少了色谱柱的劣化,防止鬼峰和基线波动,消除了过多的检测器噪音,并保持仪器良好的工作性能。
塑料本体有助于检查指示剂和更换滤芯。然而,它也可能使污染物扩散到仪器并可导致氦气泄漏。为了解决这个问题,岛津超净气体过滤器设计成外面包裹塑料,吸附剂填充在玻璃管内,由此防止扩散。
易于读取指示剂
岛津超净过滤器设计了易于读取的指示剂,当吸附剂饱和需要更换滤芯时会有颜色变化。
超净过滤器套件
p/n | 描述 |
227-37001-02 |
shimadzu carrier gas filter kit includes one 1-position base plate with m type connectors, one oxygen/moisture/hydrocarbon filter |
227-37003-01 |
shimadzu gas filter kit for gc-fid/fpd includes one 3-position base plate with m type connectors, one oxygen/moisture/hydrocarbon filter for carrier gas, two hydrocarbon/moisture filters for h2 and air |
227-37002-01 |
shimadzu gas filter kit for gc-ecd includes one 2-position base plate with m type connectors, one oxygen/moisture/hydrocarbon filter for carrier gas, one oxygen/moisture filter for nitrogen |
227-37003-02 |
shimadzu gas filter kit for compressed air includes one 3-position base plate with m type connectors, one oxygen/moisture/hydrocarbon filter for carrier gas, one hydrocarbon/moisture filter for h2, one hydrocarbon filter for compressed air |
227-37001-01 |
shimadzu makeup gas filter kit for separate makeup gas includes one 1-position base plate with m type connectors, one hydrocarbon/moisture filter |
227-37001-03 |
shimadzu carrier gas filter kit for gc-ms includes one 1-position base plate with m type connectors, one oxygen/moisture/hydrocarbon helium-specific filter |
更换滤芯
p/n |
描述 |
227-37011-01 |
shimadzu carrier gas filter (oxygen/moisture/hydrocarbon) |
227-37011-02 |
shimadzu combi gas filter (hydrocarbon/moisture) |
227-37011-04 |
shimadzu combi gas filter for nitrogen (oxygen/moisture) |
227-37011-03 |
shimadzu single gas filter for air (hydrocarbon) |
227-37011-05 |
shimadzu helium-specific carrier gas filter (oxygen/moisture/hydrocarbon) |
备件及附件
p/n |
描述 |
227-37021-01 |
base plate 1-position with m type connectors |
227-37022-01 |
base plate 2-position with m type connectors |
227-37023-01 |
base plate 3-position with m type connectors |
227-37031-01 |
通用环形螺母 (1 pc) |
227-37031-02 |
底座o型圈 (10 pcs inlet, 10 pcs outlet) |
227-37031-04 |
flush盖 (2 pcs) |
227-37032-01 |
岛津m型接头 (1 pc inlet, 1 pc outlet) |
227-37033-01 |
电子指示器 |
670-11514 |
检漏液 (240 ml) |
201-36688 |
压缩空气用水分捕集器 |
p/n |
描述 |
221-81250-01 |
gas supply pipe assy for 3-position filter kit includes three gas supply pipes for shimadzu gc side, one left-thread hydrogen gas supply pipe for cylinder side. |
201-48067-05 |
carrier gas supply pipe (5 m) |
221-18990-50 |
hydrogen gas supply pipe (5 m, right thread) |
201-48070 |
air supply pipe (1 pc of 2 m, 1 pc of 1 m) |
岛津电子天平预热后不可立即进行称量,应进行短暂的加载和卸载,为电子天平进行预压。由于在岛津电子天平通电预热时间内电子天平的传感器处于休眠状态,此时其恢复性能欠佳,如果立即进行称量,将影响到电子天平加载后的回零效果
1)岛津天平应安装在稳固水泥台上,天平脚上必须有背母及三个脚垫,这样才能达到防震要求,二个底脚作用是调节水准仪气泡在圆环内(即认为天平水平),然后才可以正确操作使用。 (2)如有足够条件,天平室内要装上空调,以保证岛津天平在
校准正确操作岛津电子天平中不可或缺的关键步骤,如果在使用电子天平的过程中不对其进行校准,就无法获得精准的计量结果。在水质检测的部门当中,很多工作人员在使用过程中认为只要天平检验合格,就不需要再进行校准工作了。其实对于天平的计量性能检验,必须包含
分析天平是一种精密仪器,每一台岛津分析天平都有相应的工作环境。在适合的环境中使用天平,才能获得精确的数据,同时也能够延长设备的使用期限。首先,天平要放置在专用的天平台上,防止天平在称量时受到震动,导致岛津天平数
岛津电子天平在使用中需要注意以下几点:第一,由于电子天平具有自动调零功能,在使用前不需要进行校准,与以往的机械天平相比较,使用程序较为便捷;第二,在使用前要注意轻拿轻放,如果用力过大会对天平内部结构造成损坏,导致称量数据失真,存在较大误差;第三,不能测量温度较高或